Step 4 move the dryer to the desired location.
Dryer exhaust vent location.
Make sure here is a good snug fit then move the band clamp over the duct connectors and tighten using a screwdriver or socket driver.
The ductwork recommended for use between the dryer in the wall should be rigid or semi rigid modeled ducting that is 4 inches in diameter.
The exhaust duct run should be as short as possible.
Dryer vent installation can be a bit of a challenge.
Use no more than 25 ft.
Proper dryer vent installation is vital to prevent fire and water damage to your home.
Step 5 connect the power supply see section 2.
Step 2 check and ensure the existing external exhaust is clean see section 1 and meets attached installation speciļ¬cations see section 3.
This also means that you can t blow the dryer exhaust into the attic or the crawlspace.
Move the dryer into position sliding the offset dryer vent connection over the dryer s discharge vent.
Models 350 and 425 install cleaner mid wall take up less cell space between the studs and allow for a more direct exhaust hose connection.
Step 6 connect the external exhaust see section 4.
The route should be as short as possible but there are other guidelines to follow when venting a dryer.
Place a 4 1 2 inch stainless steel band worm gear hose clamp over the dryer s discharge vent.
Most traditional dryers have an exhaust opening on back side of the dryer s housing.
You must terminate your dryer vent outside the building according to section m1502 of the irc.
Frequently asked questions faqs about clothes dryer venting.
Accordingly many homes have a dryer vent exhaust opening cut through the wall directly behind where a dryer.
Step 3 remove the foam shipping pads see section 1.
Check your manufacturer s instructions on how to install a dryer vent for longer distances.
A correctly installed dryer vent keeps your home safe by removing mois.
Do not use plastic or thin foil ducting.
Duct and subtract 5 ft.
Clean old ducts before installing the dryer.
Keep in mind these rules of thumb.
Your new dryer is shifted to vent to the rear.
The shorter the distance and fewer the turns the better for dryer vent installation.
The first step of installing a dryer vent in a new location is to map out a path for the ductwork.
For every 90 degree turn and 2 1 2 feet for every 45 degree turn for dryer vent installation.
The length of the run should be no more than 25 feet.
Vent distances terminations location routing draft boosters lint filters fire safety vent booster fans vent length diameter materials cleaning and other dryer vent.