Earth leakage protection response time of high sensitivity residual current devices 30 ma response time the response time of a residual current device is the time between the appearance of a dangerous leakage current and circuit power down.
Earth leakage relay pdf.
Realtime monitoring of leakage current.
Earth leakage relay for non linear loads like ups invertor drives other applications h series elr.
Applications rec max mp.
Manufactures the most trusted dependable earth leakage relays for more than 15 years and they are time tested h series earth leakage are different from other normal leakage relays.
On request toroidal oval wgc series.
Manual test button for relay operation checking.
ø 25 mm ø 35 mm ø 55 mm ø 80 mm ø 115 mm ø 140 mm ø 180 mm 220x105 mm 350x150 mm 500x200 mm.
If any current leaks from any electrical installation there must be any insulation failure in the electrical circuit it must be properly detected and prevented otherwise there may be a high chance of electrical shock if anyone touches the installation an earth leakage circuit breaker does it efficiently.
Elm earth leakage protection relay user manual 121408 issue 4 15 02 11 elm manual issue 4 121408 150211 pdf designed and manufactured in australia by ampcontrol pty limited acn 000 915 542 phone.
The term h denotes harmonics prok dv s make h series is.
Connection check open short flush mount features version 8 04 user guide for model.
02 4956 5899 fax.
Earth leakage circuit breaker or elcb.
Measuring relay and protection equipment functional requirements for over under current protection.
Types ac a si fault current ma maximum response time ms q 15 ma no tripping q 30 ma 300 ms.
Measuring relay and protection equipment.
The mh earth leakage relay series are combined with a wide range of zero phase current transformers with diameter sizes from 35mm to 140mm providing the maximum application flexibility for an effective protection in every point of the system.
Tm 8000s numerical based earth leakage relay flush mount type all measurement in millimeters side view 98 98 92 92 panel cut out 92 x 92 mm front view panel.
An elcb is a specific type of latching relay that has a structure s incoming mains power associated through its switching contacts so that the circuit breaker detaches the power in an unsafe condition the elcb notices fault currents of human or animal to the earth wire in the connection it guards.
Programmable relay output programmable software lock selectable frequency 50 60 hz auto z c t.
Earth leakage relays nv zha this kind of relay is an electrical self holding type called as harmonic surge ready type and is suitable to use in the inverter circuit can to have the active filter and the dpdc circuit.
Means it detects the earth leakage current and.